Home / Article / ขั้นตอนการก่อสร้าง
ขั้นตอนการก่อสร้าง
Home / ขั้นตอนการก่อสร้าง

CONCRETE FLOORS

Line

CONCRETE FLOORS

Line
                    
 
General concrete floors are precasted concrete plank "PCM" products. Safety imposed for live load 200 Kg/sq.m. (The regulation of Live load for residential areas is 150 kg/sq.m only).
 CONSTRUCTION METHOD
1. We use 'PCM" precasted concrete Plank 3-legs type to release deflection of plank during on concrete toping procedure.
2. Providing the temporary support at mid span for over 4.00 m. span of planks.
3. This type of floor planks convenience to leveling all floor and maintained floor strengthen.
4. Concrete topping 0.04 m. with RB 6 @ 0.20# or wire mesh dia.4 mm. @0.20#.
5. First floor concrete shall with waterproof admixtures to prptect under ground moisture will effect to flooring materials.